CMX Standard Algorithms
|
INPUT ALGORITHMS
|
|
INPUT ALGORITHMS
|
|
FILTER ALGORITHMS
|
| Hardware
linear input from 4-20 MA device with gain |
|
High Precision Steam Flow Compensator |
|
Exponential
Filter
|
| Hardware square root input from 4-20 MA device with gain |
|
Molecular Weight, Pres, Temp Compensation (Psia, Deg) |
|
Average up to 10 PVS |
| Rohrback Corrosion Monitor input |
|
Specific Gravity, Pres, Temp Compensation (Psia, Deg) |
|
Average up to 20 PVS |
| Rohrback Check Value input |
|
LMS of Database Inputs |
|
Average up to 50 PVS |
| Linear Hardware input percent of counts range with gain |
|
Variance
of Database Inputs with gain |
|
Delay 10 Filter |
| Square Root Hardware input percent of counts range with gain |
|
8 State Digital Input from Hardware |
|
Delay 20 Filter |
| 5th Order Polynomial Input |
|
Full Value Input from Hardware |
|
Delay 50 Filter |
| General Equation Input |
|
Cold Junction Reference Temperature from Hardware |
|
5th Order Polynomial |
General Hardware Temperature Linearization
Type - J, K, T, E, DIN RTD |
|
Do Nothing |
|
CONTROL ALGORITHMS
|
| Linear Input From Database with gain |
|
PLC Real Value Input |
|
Full
PID. |
|
Square Root Input From Database with gain
|
|
16 Bit Hardware Totalizer |
|
PI
Only Controller. |
| Specific Gravity Compensation |
|
32 Bit Hardware Totalizer |
|
I
- Only Controller. |
| Molecular Weight, Pres, Temp Compensation |
|
Gulton PID Image Tag Master Template |
|
OUTPUT ALGORITHMS
|
| Specific Gravity, Pres, Temp Compensation |
|
Gulton Octet Image Tag Master Template |
|
Output to Database. |
| Four Digit BCD Input |
|
Honeywell PID Image |
|
Two Bit Digital Output to Hardware. |
| Heat Exchanger BTU Calc |
|
Reliance AutoMate Thermostat Image Tag Master Template |
|
One Bit Digital Output to Hardware. |
| Mixed Fuel BTU Calc |
|
Modicon PID Image Tag Master Template |
|
Direct Analog Output to Hardware. |
| Two Feed Furnace BTU Input |
|
Reliance AutoMate No Ramp Image Tag Master Template |
|
Raw Value Output to Hardware. |
| Subtract Furnace Feeds Heat |
|
Reliance AutoMate Ramp Image Tag Master Template |
|
13-32. For user defined algorithms in the ACS Control. |
| Composition
Blend Feed forward |
|
Reliance AutoMate Timer Image Tag Master Template |
|
ALARM ALGORITHMS
|
| Sum of Database Inputs with gains |
|
Full Value Multi Fetch from Hardware |
|
Absolute PV Alarm.
|
| AND of Database Boolean Inputs with Negation |
|
Full Value Multi Store to Hardware |
|
PV Deviation Alarm.
|
| OR of Database Boolean Inputs with Negation |
|
Multi Bit Digital Fetch From Hardware |
|
PV Rate of Change Alarm.
|
| Average of Inputs with gain |
|
Multi Bit Digital Store to Hardware |
|
Digital
State Alarm
|
| Single Digital Input from Hardware |
|
Analog Devices PID Image |
|
Digital
Feedback Time Alarm. |
| Double Digital Input from Hardware |
|
Reliance AutoMate Manual Loading Station Image Tag Master |
|
Delay
Alarm |
| Standard Deviation of Inputs with gain |
|
Reliance AutoMate Register Image Tag Master Template |
|
24-32.
UNUSED - Available for user coded algorithms in the ACS Language. |
| Ratio of Two Database inputs with gain |
|
General Date/Time Stamp YY/MM/DD/-HH/MM/SS Store to Hardware |
|
|
| High Select of Database Inputs with gain |
|
Multiplication of Two Inputs with gain |
|
|
| Low Select of Database Inputs with gain |
|
Algos100-128. Available for user coded algorithms in the ACS Language |
|
|